<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/">
	<channel>
		<copyright>Copyright 1998 - 2023 DPG Media B.V.</copyright>
		<pubDate>Wed, 11 Jan 2023 23:10:13 GMT</pubDate>
		<lastBuildDate>Wed, 11 Jan 2023 23:10:13 GMT</lastBuildDate>
		<docs>https://tweakers.net/reviews/76</docs>
		<description>Tweakblogs.net is de weblog service van Tweakers, de grootste hardwaresite en techcommunity van Nederland.</description>
		<image>
			<link>https://tweakblogs.net/</link>
			<title>Tweakblogs.net</title>
			<url>https://tweakers.net/g/if/logo.gif</url>
			<height></height><width></width>
			<description>Tweakblogs.net</description>
		</image>
		<language>nl-nl</language>
		<link>https://janjeen.tweakblogs.net</link>
		<title>Het WTW project</title>
		<webMaster>gathering@tweakers.net</webMaster>
		<item>
			<title>3D geprinte Cycloon voor bouwstofzuiger</title>
			<link>https://janjeen.tweakblogs.net/blog/19488/3d-geprinte-cycloon-voor-bouwstofzuiger#r_270688</link>
			<description>hartstikke leuk, maar een cycloon kost erg weinig als je &#039;m via Ali bestelt. Ik heb er nu een jaar of 4 eentje in gebruik in mijn garage en ik kan je verzekeren; er komt echt vrijwel niks meer in je stofzuiger terecht!</description><dc:creator>Hkuit</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/19488/3d-geprinte-cycloon-voor-bouwstofzuiger#r_270688#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/19488#r_270688</guid>
			<pubDate>Tue, 15 Jun 2021 09:15:13 GMT</pubDate>
		</item>
		<item>
			<title>3D geprinte Cycloon voor bouwstofzuiger</title>
			<link>https://janjeen.tweakblogs.net/blog/19488/3d-geprinte-cycloon-voor-bouwstofzuiger#r_270450</link>
			<description>Tof dat je het geprint hebt!
Ik heb er 1 gekocht en getest icm mijn alleszuiger (Bosch) tijdens het sleuven freesen.
Dat ging echt fantastisch, nagenoeg al het stof en ook het grovere vuil bleef in de emmer.

Helaas heeft die stofzuiger maar 1 stand: aan en die zoog flinke onderdruk in de emmer die deukte daardoor in.
Maar ik durf het nu wel aan met mijn gewone stofzuiger.</description><dc:creator>Gman</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/19488/3d-geprinte-cycloon-voor-bouwstofzuiger#r_270450#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/19488#r_270450</guid>
			<pubDate>Fri, 11 Jun 2021 09:42:31 GMT</pubDate>
		</item>
		<item>
			<title>3D geprinte Cycloon voor bouwstofzuiger</title>
			<link>https://janjeen.tweakblogs.net/blog/19488/3d-geprinte-cycloon-voor-bouwstofzuiger#r_270426</link>
			<description>Hm interessant zo, eens in verdiepen!</description><dc:creator>Mattie112</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/19488/3d-geprinte-cycloon-voor-bouwstofzuiger#r_270426#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/19488#r_270426</guid>
			<pubDate>Thu, 10 Jun 2021 20:26:29 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240172</link>
			<description>Goedemorgen JanJeen,

Ik moet zeggen dat het een superleuk project is, wel heb ik een paar kleine vraagtekens...
- Heb je rekening gehouden met het eventueel invriezen van je uitgaande lucht? (vochtig) bij buitentemperaturen onder de nul graden Celcius.
   Mocht je willen dan kun je door een onbalans te creëren in de ventilatie dit voorkomen.

Knockout lig je nog niet bij 15.000 ppm, zelfs bij 30.000ppm mag een monteur koude/luchttechniek nog zonder hulpmiddelen op werken... al is de werkduur dan wel beperkt. Gezond is vanzelf wel iets anders...

Uit meetwaarden uit het rapport van de gemeente Amsterdam (gezonde scholen project) blijkt dat i.s.m. het GGD en enkele fabrikanten is vastgesteld dat met een bezetting van 30 leerlingen de CO2 waarden slechts driemaal per dag boven de 800ppm komt bij een ventilatievoud van ongeveer 3.

Een goed binnenklimaat hangt af van heel veel factoren, Middels CO2/CO metingen kunnen deze twee &#039;makkelijk&#039; te meten waarden goed beheersbaar blijven.
De RV en fijnstof hoeveelheid is echter moeilijker in de hand te houden; om deze reden wordt er steeds meer gefocused op de CO2 waarde.

Wat betreft de CO2 waarde in de atmosfeer zoals gemeten door de NASA, moet je wel meenemen dat de meetwaarden in 1950 van een significant slechtere kwaliteit waren als tegenwoordig. Hiernaast was de hoogte waarop men de meting verrichte niet vast te stellen/ te controleren. Zoals in het volledige rapport vermeld zijn alleen de metingen van de laatste twintig jaar geverrifieerd door derden...</description><dc:creator>WimOBL</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240172#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_240172</guid>
			<pubDate>Mon, 04 Feb 2019 08:35:28 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240164</link>
			<description>Voor nog meer CO2 hier nog een gast video op het kanaal van Tom Scott:
https://www.youtube.com/watch?v=1Nh_vxpycEA</description><dc:creator>Tim_bots</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240164#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_240164</guid>
			<pubDate>Mon, 04 Feb 2019 07:27:40 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240068</link>
			<description>Erg leuk al die reacties! 

Ik blaas nu in op de zolder slaapkamer en één slaapkamer aan de voorzijde. Het gordijn sluit absoluut niet luchtdicht af en is zelf ook dampopen.
Daarmee is het nog geen complete balansventilatie. In mijn woonkamer zit geen invoer en staat er gewoon een luchtrooster in een raam open. 

CO2 in huis blijkt een nog redelijk on ontgonnen terrein in de wetenschap. Artikelen die je het Nederlandse nieuws leest zijn niet diepgaand en erg eenzijdig.

Een erg interessant artikel op dit gebied komt van Nasa: A Review of Cognitive and Behavioral Effects of Increased Carbon Dioxide Exposure in Humans.
Hierin worden verschillende studies naast elkaar gelegd. Uit hun conclusie: &quot;...the 
inconsistent and contradictory nature of current findings limits the ability to draw firm conclusions about the impact of elevated CO2 exposure on sleep, cognition, and psychomotor performance&quot;
Oftewel, er is geen feitelijke onderbouwing voor bepaalde grenswaarden, zoals &quot;1000ppm is de gezonde bovengrens&quot;. Bij 2400ppm lig je echt niet knock-out. Optimaal is het vast ook niet, maar met vrieskou kan ik de buitendeuren niet open zetten. Mijn ventilatie op stand 3 en afzuigkap is blijkbaar niet toereikend voor zoveel mensen. Ik ben wel benieuwd wat voor waarden jullie meten in bij veel mensen in 1 ruimte. 
De Netatmo heeft een accuraatheid van ± 50ppm tot 1000ppm en ± 5% voor metingen boven de 1000ppm, volgens fabrikant.

Waar ik van schrok is dat het CO2 niveau volgens Nasa elke 10 jaar met 22ppm omhoog schiet en dat we nu al op het dubbele niveau zitten van wat eeuwen lang gebruikelijk was. Als je die lijn lineair doortrekt zal de atmosfeer we in 2060 op 500ppm zitten.

De Holdpeak flowmeter is in bestelling, want Ik ben ook wel benieuwd naar de meetwaarden.</description><dc:creator>JanJeen</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240068#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_240068</guid>
			<pubDate>Sat, 02 Feb 2019 07:26:06 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240048</link>
			<description>Mooi project.  In welke kamers heb je nu de inlets zitten? Lijkt me ook wel mooi om het debiet van je systeem op verschillende plekken te meten, en het geluidsniveau naast de ventilatiekast en bij de inblaasventielen.

Op de foto van het inblaasventiel zie ik dat deze achter de gordijnrails hangt. Als het gordijn helemaal dicht is, verwacht ik dat het ventilatiedebiet daar enorm afneemt door de luchtweerstand van de gordijnstof. En juist in slaapkamers neemt &#039;s-nachts, wanneer de gordijnen dicht zijn, het CO2-gehalte flink toe. </description><dc:creator>Coffeemonster</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240048#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_240048</guid>
			<pubDate>Fri, 01 Feb 2019 15:52:59 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240000</link>
			<description>^^ Eensch dat de RV niet relevant is. Even de cijfers:

Een kuub droge lucht kost je ongeveer 1.5 kJ om 1 graad op te warmen.

Een kuub lucht van 20 graden en 70% RV bevat 13 gram water. Dat water heeft per gram 4.3 J nodig om 1 graad op te warmen. 13 gram water heeft dus 55 joules nodig om 1 graad op te warmen. 
Ofwel; lucht van 70% RV bij 20 graden heeft 3.5% meer energie nodig om 1 graad op te warmen wanneer het vergeleken wordt met 21 graden en 0% RV; ofwel zo&#039;n 0.05% meer energie per procent aanwezige luchtvochtigheid is nodig om lucht op te warmen.

Dus de stelling klopt dat vochtige lucht meer energie nodig heeft om op te warmen, echter is de hoeveelheid extra energie te verwaarlozen </description><dc:creator>Theo</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_240000#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_240000</guid>
			<pubDate>Thu, 31 Jan 2019 21:43:13 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239998</link>
			<description>Marvin- schreef op donderdag 31 januari 2019 @ 13:09:
Hoe meet je de temperatuur van de lucht? Kan ook nogal afwijken hoe vochtig het buiten / binnen is. De soortelijke warmte van lucht is sterk afhankelijk van vocht; hoe meer water, des te meer energie het kost om op te warmen (dus je kan beter kijken naar energiebalans ipv dT).Het verschil in soortelijke warmte tussen normale en vochtigere lucht, laten we zeggen 50 en 80%, is nog geen 0,5%. Valt erg mee dus.</description><dc:creator>Joepla</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239998#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_239998</guid>
			<pubDate>Thu, 31 Jan 2019 21:26:05 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239990</link>
			<description>@Marvin, juist in jouw situatie zou een balansventilatie een uitkomst zijn! De lucht die naar binnen wordt geblazen kun je ook door een filter laten gaan welke fijnstof tegenhoudt. Dan heb je wel een goede ventilatie in huis en een continue luchtverversing in huis, maar niet het geluid, de fijnstof en zooi van buiten 

Ik heb thuis hetzelfde; een (deels) zelfbouw WTW met daarin een dik F6 filter dat veel fijnstof, pollen en muggen tegenhoudt; en ik woon ook zo&#039;n 500 meter van de snelweg vandaan. Dus wel de ventilatie en verse lucht in huis, maar geen herrie, pollen, fijnstof en muggen..</description><dc:creator>Theo</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239990#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_239990</guid>
			<pubDate>Thu, 31 Jan 2019 17:07:27 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239974</link>
			<description>Leuk project! In mijn huis helaas niet toepasbaar, wat ik wel graag zou willen. Ik woon namelijk dicht bij een grote weg en een raampje openzetten wordt ik niet altijd blij van ivm NOx en fijnstof. 

Hoe meet je de temperatuur van de lucht? Kan ook nogal afwijken hoe vochtig het buiten / binnen is. De soortelijke warmte van lucht is sterk afhankelijk van vocht; hoe meer water, des te meer energie het kost om op te warmen (dus je kan beter kijken naar energiebalans ipv dT). 

Om reëel na te gaan hoeveel energie bespaart zou je dus ook de luchtvochtigheid kunnen meten, icm nauwkeurige temperatuur metingen (zitten ze bijv in het midden van de flow/ pijp?)

Je kan ook eens kijken naar jouw huisprofiel en dan een aanname maken over je &#039;leakage rate&#039; (verversingssnelheid van totale lucht versus nieuw lucht in uren), daar zijn een aantal standaardwaarden voor bekend in de literatuur.</description><dc:creator>Marvin-</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239974#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_239974</guid>
			<pubDate>Thu, 31 Jan 2019 12:09:30 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239924</link>
			<description>Eens met @Theo, de ppm&#039;s zijn nog vrij hoog.
Ik heb geen WTW maar gewoon mechanische ventilatie. Heb een CO2 sensor gebouwd (obv MH-Z19) en laat de ventilatiebox naar stand 2 sturen als ppm &gt;= 800ppm is. En naar stand 3 bij &gt;=1200ppm

Met een verjaardag zit ik op 1500 ppm in de woonkamer en dat vond ik eigenlijk al schrikbarend veel. Met jouw 2400 ppm zou iedereen knock-out in de woonkamer moeten liggen? Hoe betrouwbaar is die Netatmo  ? En heb je ook roosters in de woonkamer? Want hoe voer je frisse lucht aan (totdat je ook in woonkamer aanvoer en toevoer vanaf WTW hebt geregeld).

Wat is trouwens de reden voor het zelf bouwen van een wisselaar en niet hergebruik van een bestaande unit zoals Theo bijv. heeft gedaan?</description><dc:creator>ThinkPad</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239924#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_239924</guid>
			<pubDate>Wed, 30 Jan 2019 20:16:08 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239892</link>
			<description>Leuk om te zien dat je idee nu ook werkelijkheid is geworden! 

Waar heb je eigelijk je tweede Itho fan verstopt?

Goed dat je ook met de CO2 bezig bent; dat is eigelijk dé reden waarom je moet ventileren. Al is 1200 ppm nog wel wat aan de hoge kant. Veel richtlijnen gaan uit van &lt;800 ppm voor een gezonde omgeving. Vanaf 1200 ppm kun je er dingen van gaan merken zoals moe, minder energie en het &#039;muf klaslokaal effect&#039;. Ik heb daarom thuis mijn (ook deels zelfbouw) WTW ingeregeld op &lt;800 PPM als vriendin en ik beide thuis zijn of beide slapen.

Om de flow te meten kun je ook een anemometer halen bij Ali. Haal er dan 1 met een zo groot mogelijk schoepenwiel. De Holdpeak hp-866b heeft het grootste schoepenwiel in een betaalbare klasse (17 euro). Zet je hier een trechter op die bestaat uit een 150-125mm verloopje voor je luchtbuizen dan kun je hier best goed de flow mee meten en je systeem in balans krijgen. (Zo&#039;n verloopje pas exact om een ventiel heen)

Je kan de flow ook beter in balans krijgen door de temperaturen van de ingaande en uitgaande lucht te meten bij je WTW. Wanneer de delta tussen beide gelijk is (bij meerdere buitentemperaturen) dan staat je balans goed. Nadeel van afstellen op deze manier is dat het een hoge doorlooptijd heeft; je kan max 2 keer per dag de debiet afstellen vanwege de thermische traagheid van je systeem. En je wil het ook in balans krijgen voor de verschillende standen?

Als je en dT hebt van 20 graden tussen binnen een buiten, en de flow naar binnen warmt maar 8 graden op dan heb je nog steeds erg koude lucht in huis en kun je in afstelling nog veel winst halen. Als je WTW zelf een goed rendement heeft dan zou de lucht naar binnen zeker met 70% van de dT opgewarmd moeten zijn.

Hoe ga je met condenswater om? Nu het buiten koud is wordt de lucht naar buiten sterk afgekoeld waardoor er condensatie optreedt. Ik heb  momenteel ongeveer zo&#039;n 1-2 liter condens per dag wat vande WTW afkomt.</description><dc:creator>Theo</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239892#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_239892</guid>
			<pubDate>Wed, 30 Jan 2019 13:36:56 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Werkend!</title>
			<link>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239888</link>
			<description>netjes hoor, doe het je niet na.</description><dc:creator>onok</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/17226/ventilatie-met-warmteterugwinning-werkend!-1.html#r_239888#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/17226#r_239888</guid>
			<pubDate>Wed, 30 Jan 2019 13:29:08 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_221279</link>
			<description>Hoe is dit project afgelopen eigenlijk?</description><dc:creator>ThinkPad</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_221279#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_221279</guid>
			<pubDate>Wed, 31 Jan 2018 18:33:25 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214747</link>
			<description>Goed punt van @govie om juist ook in aanvoer van buiten niet te vergeten. Zorg ervoor dat dit pad zo kort mogelijk is, of dat dit echt heel goed geisoleerd is!

Niet allen om condens tegen te gaan maar ook omdat de binnenkant van de buis (thermisch gezien) gelijk staat aan de buitenlucht, en de omgeving van die buis dus binnen in huis is. Isoleer je deze buis niet dan heb je een enorme koudebrug van buiten naar binnen.

Zonder isolatie van deze buis heb je een oppervlakte van 0.5m2 per lengtemeter buis waarbij je enkel een 1mm dunne metalen wand hebt tussen buiten en binnen, en dat is een enorm slechte isolatie. 
Je warmteverlies weegt dan niet op tegen het rendement van je WTW.


Mijn WTW hangt op de vliering.  De vliering is niet geisoleerd, de rest van het huis wel. Hierdoor hangt, thermisch gezien, de WTW buiten. Ik heb daarom om ALLE buizen waar binnenlucht doorheen stroomt geisoleerd met 20CM aan glaswol.
Jouw WTW hangt, thermisch gezien, binnen. Isoleer daarom beide buizen met koude (buiten) lucht, en isoleer ze niet zuinig.</description><dc:creator>Theo</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214747#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214747</guid>
			<pubDate>Fri, 13 Oct 2017 12:50:39 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214707</link>
			<description>De lucht die je van buiten trekt is soms -10 graden, daardoor moet je de aanzuigroute, de wisselaar en je afblaasroute wel geïsoleerd uitvoeren om condensatie te voorkomen. Dat is de reden waarom veel fabrikanten een samengesteld frame maken uit PPE/piepschuim achtig materiaal. Je kunt daar vrij simpel vormen in aanbrengen met hitte elementen zoals soldeerbouten en hitte draden om mee te snijden, maar dat spul is ook bewerkbaar met verspanend gereedschap. Het is dus heel erg goedkoop om vormen in aan te brengen, pak wel een materiaal met voldoende sterkte, ze hebben meerdere klassen. Je kan altijd nog verstevigingsmatyeriaal toevoegen aan die blokken piepschuim/ppe. Dan kun je daaromheen een omkasting en een montageframe waar alles op rust. Ik heb zelf ooit een aantal wtw ventilatie units ontworpen en ik vond deze manier het prettigst omdta het goedkoop materiaal is, goedkoop bewerkbaar is, maar ook omdat de fabrikanten dezelfde methoden gebruiken bij wtw units. In principe kan je zo&#039;n piepschuim/ppe wtw frame op de keukentafel of schuur snijden met een hittedraad.</description><dc:creator>govie</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214707#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214707</guid>
			<pubDate>Fri, 13 Oct 2017 06:23:40 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214687</link>
			<description>Johnny321 schreef op donderdag 12 oktober 2017 @ 11:31:
Met die ventilator gaat het inderdaad niet lukken om de lucht door de fitlers te blazen; en laten we het niet over de herrie hebben; ventilatie moet je in principe niet horen als je &#039;s nachts op je bedje ligt Jullie hebben mij overtuigt, ik ga kijken of ik ergens in het ontwerp toch nog een grote ventilator kwijt kan!Theo schreef op donderdag 12 oktober 2017 @ 11:54:
Voor de filters kun je ook op zoek gaan naar een rol van het filtermateriaal. Voor een standard setje filters voor een WTW unit betaal je al snel 30 euro. Terwijl als je het filterdoek op rol koopt je voor hetzelfdfe geld er 10 filters uit kunt knippen.

Ik zou trouwens wel nadenken over je filter en je filterklasse, helemaal als je bij een drukke weg woont of je met hooikoorts te maken hebt. Dan is een klasse G4 of beter wel een aan te raden minimum.Goede tips! Theo, ik ben dankzij jou en het internet weer een boel wijzer geworden over luchtfilters. Ik denk nu aan een G3 of G4 filter om vervuiling van de wtw tegen te gaan en verderop in de ventilatiebuizen een filterbox voor de afvang van fijnere stofdeeltjes. Daar heb ik namelijk nog wat extra ruimte voor een zo&#039;n box. To be continued!</description><dc:creator>JanJeen</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214687#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214687</guid>
			<pubDate>Thu, 12 Oct 2017 20:24:51 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214601</link>
			<description>Voor de filters kun je ook op zoek gaan naar een rol van het filtermateriaal. Voor een standard setje filters voor een WTW unit betaal je al snel 30 euro. Terwijl als je het filterdoek op rol koopt je voor hetzelfdfe geld er 10 filters uit kunt knippen.

Ik zou trouwens wel nadenken over je filter en je filterklasse, helemaal als je bij een drukke weg woont of je met hooikoorts te maken hebt. Dan is een klasse G4 of beter wel een aan te raden minimum. 


Zorg iig voor een zo groot mogelijk filteroppervlakte om de benodigde luchtdruk zo lag mogelijk te houden. Hierdoor wordt je system zuiniger, en je hoeft minder vaak de filters te vervangen.</description><dc:creator>Theo</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214601#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214601</guid>
			<pubDate>Thu, 12 Oct 2017 09:54:26 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214599</link>
			<description>Met die ventilator gaat het inderdaad niet lukken om de lucht door de fitlers te blazen; en laten we het niet over de herrie hebben; ventilatie moet je in principe niet horen als je &#039;s nachts op je bedje ligt 
Voor een filter zou ik een standaard filter aanschaffen van Brink of en ander fabrikaat; deze kun je dan zo in je behuizing schuiven.</description><dc:creator>Johnny321</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214599#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214599</guid>
			<pubDate>Thu, 12 Oct 2017 09:31:31 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214597</link>
			<description>JanJeen schreef op woensdag 11 oktober 2017 @ 21:26:

 
[...]
Ik ben benieuwd welke axiale ventilator je destijds hebt gebruikt? Ik moet zeggen dat het idee van 2 Itho Ecofans ook niet verkeerd klinkt.Ik gebrukte een industriele 11 watt fan die een PQ curve had die redelijk lineair liep van 200PA/0m3/h naar 0 PA/125m3/h

Ik had een druk nodig van ongeveer 120PA om alle lucht door een filter en de WTW te blazen. Mijn fan trok het wel, maar kon niet meer dan 35 m3/uur blazen. Ik kon met een electrisch vermogen van 13 watt  (11 watt plus 2 watt voor m&#039;n AC/DC voiding) 35 m3 aan luchtverplaatsing krijgen

Zo&#039;n Ithobox box trok het met gemak (ook omdat deze groter is). Deze staat momenteel op ongeveer 85m3/uur ingesteld, en heeft daarbij een stroomverbruik van 9 watt per stuk. Plus, ik kan &#039;m omhoogzetten naar ongeveer 175 m3 mocht dat nodig zijn.

De losse fan verbruikt daarmee 0.37W per m3/h aan stroom. De Itho is met 0.10 W per M3/h een heel stuk zuiniger.

Plus, zo&#039;n industriele fan maakt nogal wat herrie...</description><dc:creator>Theo</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214597#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214597</guid>
			<pubDate>Thu, 12 Oct 2017 08:06:02 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214565</link>
			<description>Coritchando schreef op maandag  9 oktober 2017 @ 10:13:
Waarom niet een WTW die de warmte afvangt en je CV installatie in stuurt?Ik wil ook ventileren met raam dicht, vandaar de WTW. Daarnaast heb je voor jouw voorbeeld een dure warmtepomp nodig om de afvoerlucht op te waarderen naar 30°C-40°C wat de CV nodig heeft. .govie schreef op maandag  9 oktober 2017 @ 21:04:
De uitvoering die jij zoekt bestaat volgens mij gewoon nog steeds af fabriek, ik heb die vroeger geinstalleerd met alles erop en eraan. Goed googlen dus, er zijn heel veel wtw fabrikaten! Ik zou er van staan te kijken als die niet meer bestaan. bijvoorbeeld brink (ik heb niet gekeken of deze voor jouw situatie voldoet, maar je komt er wel uit). Er zijn tiental van dit type modules op de europese markt, je vind ze wel met wat zoeken. Als je toch zelf gaat hobbyen vergeet dan niet een vorstregeling, anders krijg je problemen in de winter, juist het seizoen wanneer de opbrengst het grootste zou zijn. Binnen een aantal minuten kan een wisselaar al dicht vriezen, dus een vorstregeling is belangrijk. Vergeet ook niet om te checken of je een unit diagonaal mag bevestigen.

Wel leuk om te vermelden: In belgie heb ik ooit een concept gezien dat ze de luchtaanvoer van een ventilatieunit  via ventilatiepijpen onder de grond van de tuin hadden lopen. De temperatuur van de grond is circa 10 graden, dus die lucht verwarmde voor in de winter en werd voorgekoeld in de zomer. Vond het wel slim gedacht, ondanks dat in de meeste woningen de ventilatie altijd op stand 1 of 2 draait, dus veel koelvermogen valt daar niet uit halen. Maargoed toch wel leuk bedacht. Natuurlijk moet je dan wel echt tientallen meters pijp hebben om een verschil te maken. Je zou hetzelfde principe ook voor de aanvoer van een warmtepomp kunnen gebruiken, als je een buitenunit heb=hoger rendement. Maargoed zoveel meter pijp is wel heel erg duur dus waarschijnlijk niet echt een besparing op een acceptabele termijn, wel leuk bedacht.Ik kies bewust voor zelfbouw omdat ik het erg leuk vind om dit te bedenken en in elkaar te zetten. Ik ga je tip voor vorstbeveiliging zeker meenemen. Daarnaast is voorverwarming van de toevoerlucht zeker interessant voor een nieuwbouwhuis.Theo schreef op dinsdag 10 oktober 2017 @ 08:55:
Ik denk niet dat je concept gaat werken;  de ventilato die je wil gebruiken heeft niet voldoende kracht om door een luchtfilter en je WTW unit te komen, simpelweg omdat zo&#039;n axiale fan niet deze druk kan leveren. JE Itho ventilatiebox heeft een radiale fan. Deze zijn erg goed is het leveren van de benodigde luchtdruk.
...
Het lukte mij met axiale fans gewoon niet om voldoende flow te krijgen.Ik ben benieuwd welke axiale ventilator je destijds hebt gebruikt? Ik moet zeggen dat het idee van 2 Itho Ecofans ook niet verkeerd klinkt.</description><dc:creator>JanJeen</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214565#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214565</guid>
			<pubDate>Wed, 11 Oct 2017 19:26:12 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214475</link>
			<description>Ik denk niet dat je concept gaat werken;  de ventilato die je wil gebruiken heeft niet voldoende kracht om door een luchtfilter en je WTW unit te komen, simpelweg omdat zo&#039;n axiale fan niet deze druk kan leveren. JE Itho ventilatiebox heeft een radiale fan. Deze zijn erg goed is het leveren van de benodigde luchtdruk.


Ik heb bij mij thuis ook een WTW unit geplaatst  in een oud huis dat geen enkele vorm van mechanische ventilatie had met een losse WTW unit en twee Itho Ecofan units (ook vanwege het gebrek aan ruimte). Het lukte mij met axiale fans gewoon niet om voldoende flow te krijgen. Gezien de kleine openingen die er bij jouw ontwerp in de inblazende luchtstroom zitten ga je het met een axiale fan echt niet redden...

Vanuit mijn ervaring kan ik je ook heel erg aanraden om een tweede ventilatiebox te halen (ze staan voor minder dan 50 euro op Marktplaats) en deze gewoon te gebruiken, je hebt dan een goede radiale fan die heel erg goed ingesteld kan worden. Ik heb thuis het systeem ingesteld op 85m3/uur afzuig en 90 m3/uur inblaas. Het stroomverbruik van beide fans is samen 17 watt.

Verder heb je een anemometer nodig om de balans te vinden tussen aanzuig en afvoer voor het inregelen van je systeem.

Persoonlijk heb ik nog wel mijn vraagtekens bij het gebruik van een kunststof warmtewisselaar. Struin Marktplaats af en haal voor 50-75 euro een losse warmtewisselaar uit een WTW systeem; dan heb je een kant en klare oplossing van aluminium. Dat moet veel beter werken dan plastic..</description><dc:creator>Theo</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214475#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214475</guid>
			<pubDate>Tue, 10 Oct 2017 06:55:45 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214455</link>
			<description>De uitvoering die jij zoekt bestaat volgens mij gewoon nog steeds af fabriek, ik heb die vroeger geinstalleerd met alles erop en eraan. Goed googlen dus, er zijn heel veel wtw fabrikaten! Ik zou er van staan te kijken als die niet meer bestaan. bijvoorbeeld brink (ik heb niet gekeken of deze voor jouw situatie voldoet, maar je komt er wel uit). Er zijn tiental van dit type modules op de europese markt, je vind ze wel met wat zoeken. Als je toch zelf gaat hobbyen vergeet dan niet een vorstregeling, anders krijg je problemen in de winter, juist het seizoen wanneer de opbrengst het grootste zou zijn. Binnen een aantal minuten kan een wisselaar al dicht vriezen, dus een vorstregeling is belangrijk. Vergeet ook niet om te checken of je een unit diagonaal mag bevestigen.

Wel leuk om te vermelden: In belgie heb ik ooit een concept gezien dat ze de luchtaanvoer van een ventilatieunit  via ventilatiepijpen onder de grond van de tuin hadden lopen. De temperatuur van de grond is circa 10 graden, dus die lucht verwarmde voor in de winter en werd voorgekoeld in de zomer. Vond het wel slim gedacht, ondanks dat in de meeste woningen de ventilatie altijd op stand 1 of 2 draait, dus veel koelvermogen valt daar niet uit halen. Maargoed toch wel leuk bedacht. Natuurlijk moet je dan wel echt tientallen meters pijp hebben om een verschil te maken. Je zou hetzelfde principe ook voor de aanvoer van een warmtepomp kunnen gebruiken, als je een buitenunit heb=hoger rendement. Maargoed zoveel meter pijp is wel heel erg duur dus waarschijnlijk niet echt een besparing op een acceptabele termijn, wel leuk bedacht.</description><dc:creator>govie</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214455#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214455</guid>
			<pubDate>Mon, 09 Oct 2017 19:04:34 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214421</link>
			<description>Wij hebben een WTW unit thuis en ik ben er erg blij mee! Zat er al in vanaf de bouw van het huis (2008). Zeker in de winter is het ideaal, constante temperatuur in het hele huis.
Als ik in de zomer warmte kwijt wil, zet ik een raam open van ons (dit jaar geplaatste) dakkapel.</description><dc:creator>harmageddon</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214421#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214421</guid>
			<pubDate>Mon, 09 Oct 2017 09:13:29 GMT</pubDate>
		</item>
		<item>
			<title>Ventilatie met warmteterugwinning - Concept</title>
			<link>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214395</link>
			<description>Waarom niet een WTW die de warmte afvangt en je CV installatie in stuurt? Onder andere Eneco is hier nu druk mee aan het testen. Lijkt mij ideaal, maar ik heb dan ook de ITHO naast de ketel hangen op de voorzolder </description><dc:creator>5183</dc:creator>
			<category></category>
			<comments>https://janjeen.tweakblogs.net/blog/15343/ventilatie-met-warmteterugwinning-concept#r_214395#reacties</comments>
			<guid isPermaLink="false">https://janjeen.tweakblogs.net/blog/15343#r_214395</guid>
			<pubDate>Mon, 09 Oct 2017 08:13:17 GMT</pubDate>
		</item>
	</channel>
</rss>